33 results (0,15483 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent COMPACT-NC Compact Network Card

Gent VIG-NC Network Card

Gent S4-34741-03 34740 Parallel Bracket and Base

Gent S4-34741-99 Light Shields for Beam Receiver Pack of 5

Gent S4-34741-01 34740 Angle Bracket and Base

Gent VSINTSC-PCB01 Spare PCB for S4 Single Channel Mains Switching IF S4-34401

Gent VSINTM-PCB12 Spare PCB for S4 Mains Powered Interface - 2.5A S4-34440-12

Gent VSINTSC-PCB04 Spare PCB for S4 Four Channel Mains Switching IF S4-34404

Gent Vigilon Plus Repeater Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 345.66
1

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 349.91
1

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 445.02
1

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 256.49
1

Gent S2IP-SN-W3 Backwards Compatible Replacement for 34203 3 Way Sounder

Gent S2IP-SN-R3 Backwards Compatible Replacement for 34203 Red 3 Way Sounder

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful software processing in the panel quickly identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredPlease note This product requires 2 x 12v 12Ah Batteries NP12-12.

GBP 1579.67
1

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card SetThe S4-34741-50 is an Obscuration Test Card Set designed for use with Gent Beam Detectors.Honeywell Gents S-Quad Beam Sensors provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire. The Gent loop powered beam is certified to EN54 parts 12 and 17.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 32.03
1

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor SounderThe GENT S4T-770-S Self-Test Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 134.18
1

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and SounderThe GENT S4T-780-S Self-Test Heat Sensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 141.83
1

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor SounderThe GENT S4T-771-S Self-Test Dual Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 156.26
1

Gent S4T-710 S4 SELF TEST Optical Heat Sensor

Gent S4T-710 S4 SELF TEST Optical Heat Sensor

Gent S4T-710 S4 SELF TEST Optical Heat SensorThe GENT S4T-710 Self-Test Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 105.31
1

Gent S4T-720 S4 SELF TEST Heat Sensor

Gent S4T-720 S4 SELF TEST Heat Sensor

Gent S4T-720 S4 SELF TEST Heat SensorThe GENT S4T-720 Self-Test Heat Sensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 100.21
1

Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor

Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor

Gent S4T-711 S4 SELF TEST Dual Optical Heat SensorThe S4T-711 Self-Test Dual Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 121.45
1

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardDoes not come with printerPlease note This product requires either4 x 12v 24Ah Batteries NP24-12 or 8 x 12v 24Ah Batteries NP24-12.

GBP 3580.97
1

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

GentVIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel 1 Loop Card without PrinterVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease Note This product requires 2 xYuasa 12V 24AH Battery Inverted Terminals NP24-12.

GBP 2431.50
1