FC410QMO Fireclass Quad Monitored Output Module

Fireclass 557.202.726FC FC MAE - FC500 Panels Monitoring Software

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 108.66
1

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder DriverThe MTL5525 Isolating Sounder Driver enables an intrinsically safe sounder located in the hazardous area to be controlled from the safe area.The barrier is designed as a CE marked replacement for the existing MTL3021 barrier. It has one channel and is suitable for connecting loads in Zone 0 IIC T4-T6 hazardous areas if suitably certified. It enables an onoff device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area. It can drive loads such as solenoids alarms LEDs and other low power devices that are certified as intrinsically safe or are classified as nonenergy storing simple apparatus.MTL5500 Series isolating IS interface units offer a compact and easy-to-use means for communicating safely with process measuring indicating actuating and local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions amplifying or otherwise conditioning them as required and at the same time providing certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. The range has been designed for reliability. It builds on the proven success of the MTL2000 3000 4000 and 5000 Series to bring the benefits of new developments in galvanic isolation without compromising the reliability of the designs from which it has evolved. It is designed from the outset to meet all relevant European Directives. Uniform appearance and connectability of the units and a comprehensive range of accessories and enclosures make planning a pleasure for the user.Key FeaturesInput Type VoltageOutput Type VoltageSignal Conditioner Type IsolationInput Range 1.4 - 4.5 V dcOutput Range 7.8 - 24 VMounting Type DIN RailMinimum Operating Temperature -20CMaximum Operating Temperature 60CNumber of Channels 1Module Type SolenoidAlarm DriverTermination CableOperating Temperature Range -20 - 60 CSeries MTL5000

GBP 165.58
1

Fireclass FC604S Four Loop Addressable Fire Panel 557.200.651FC

Fireclass FC604S Four Loop Addressable Fire Panel 557.200.651FC

Fireclass FC604S Four Loop Addressable Fire PanelThe FC604S is a four loop FireClass networkable panel with a shallow housing. This panel can have four standard-power loops or two high-power loops with each panel having a maximum of 500 addresses. It features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17 Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs.The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform. The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users.The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 981.83
1

Fireclass FC602S Two Loop Addressable Fire Panel 557.200.650FC

Fireclass FC602S Two Loop Addressable Fire Panel 557.200.650FC

Fireclass FC602S Two Loop Addressable Fire PanelThe FC602S is a compact two-loop FireClass networkable panel with a shallow housing. It can have two standard-power loops or one high-power loop with each panel having a maximum of 250 addresses. The panel features a colour LCD display with 32 zonal LEDs and has a maximum capacity of 17Ah batteries.The FC600 FireClass range is a powerful fire detection and alarm system that uses the robust FireClass loop protocol at its heart. The FireClass loop protocol was originally designed for operation in the most hostile of environments therefore the system is highly resilient to external factors such as electrical noise including interference from electrical signals from other devices and sources of false alarm. The FC600 FireClass range uses the same hardware and software platform already well-known from the FC700 FireClass panel range.It also brings a new FireClass Colour User Interface FC-CUI making it the perfect choice for small to mid-size systems up to 500 devices while keeping cost efficiency in mind. The panel has been specifically engineered to offer increased loop capacity and the option to share loops giving even more flexibility in the systems design and a reduction in installation costs. The new concept of high-power loops makes it easy to migrate from legacy FireClass range to new FC600 platform.The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users. The FC600 range offers integrated fire detection solutions for many mid-size applications including hotels commercial offices healthcare environments industrial and manufacturing facilities.Key FeaturesColour LCD display with 32 zonal LEDsSimple to operate user interfaceFlexible loop configurations with up to 1A current to increase use of loop power and address capacityComprehensive point management10000 event logEditable quiescent display textExtensive special cause and effect programmingManual and automatic walk testAutomatic battery testDetector service functionsFront panel controls enabling text and configuration changesNetworkableUp to seven fully functional repeatersOptional easy-mount plateOptional expansion kit for mounting additional cards

GBP 765.65
1

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 388.25
1

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 429.75
1

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 417.85
1

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 PointsThe FC503 is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC503 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC503 panel has 3 in 1 loops that can support up to 250 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC503 control panel supports up to 250 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 602.35
1

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 PointsThe FC506is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC506is an out of the box panel which offers thesimplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC506 auto-addressing panel has 6 in 2 loops that can support up to 500 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC506control panel supports up to 500 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features 6 in 2 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 894.93
1