51 results (0,13275 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec W921000W8 Sigma ZSi - 6 LED Weatherproof Extinguishant Status Unit

Kentec K921000M8 Sigma ZSi - 6 LED Extinguishant Status Unit

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone ConventionalSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4.Up to 8 zones of conventional detection with up to 4 extinguishant areas are available.Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable.The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort input

GBP 1634.28
1

Kentec W921100W8 Sigma ZSi - 6 LED Weatherproof Extinguishant Status Unit cw Mode Select Key Switch

Kentec K921100M8 Sigma ZSi - 6 LED Extinguishant Status Unit cw Mode Select Key Switch

Kentec K921010M8 Sigma ZSi - 6 LED Extinguishant Status Unit cw Manual Release

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control Panel

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control Panel

Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boardsExtinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC input

GBP 650.87
1

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Dual action manual extinguishing release control AutoManual keyswitch 3 Amp power supply 230V AC input

GBP 1349.23
1

Kentec K85001BLU BMS License Upgrade

Kentec W921110W8 Sigma ZSi - 6 LED Weatherproof Extinguishant Status Unit cw Manual Release amp Mode Select Key Switch

Kentec Sigma CP Ancillary PCB K580

Kentec K921110M8 Sigma ZSi - 6 LED Extinguishant Status Unit cw Manual Release amp Mode Select Key Switch

Kentec K01080M2 Sigma CP-R 8 - Zone Conventional Repeater Panel with PSU2

Kentec K01040M2 Sigma CP-R 4 - Zone Conventional Repeater Panel with PSU2

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1092.69
1

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1030.93
1

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel

Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 950.17
1

Kentec K921113M8 Sigma ZSi - 10 LED Extinguishant Status Unit cw Manual Release amp Mode Select Key Switch

Kentec W921113W8 Sigma ZSi - 10 LED Weatherproof Extinguishant Status Unit cw Manual Release amp Mode Select Key Switch

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A

GBP 593.85
1

Kentec Sigma CP-R Repeater Panel with 230v PSU amp Standard Enclosure 2 - 8 Zone

Kentec Sigma CP-R Repeater Panel with 230v PSU amp Standard Enclosure 2 - 8 Zone

Kentec Sigma CP-R Repeater Panel with 230v PSU Standard Enclosure 2 - 8 ZoneThe Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2 4 or 8 zones and in mains powered K versions or 24V powered E versions. Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.A mixture of Repeaters Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.Key FeaturesSigma CP-R Two wire serial connectionUp to 7 panels per system230V AC or 24V DC powered versionsFull control over main panelVolt free fire and fault contact outputsAncillary PCB Two wire serial connectionUp to 7 boards per system230V AC or 24V DC powered versionsOpen collector zonal fault outputsVolt free fire coincidence and common fault contact outputsVariants AvailablePart NumberDescriptionK01020M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 2 Zones SurfaceK01040M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 4 Zones SurfaceK01080M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 8 Zones Surface

GBP 239.04
1

Kentec Syncro 16 Channel Input Output Board K560

Kentec Syncro 16 Channel Input Output Board K560

Kentec Syncro 16 Channel Input Output Board K560To add more IO capablity to the extensive options already offered by the Syncro control panel up to thirty two sixteen channel IO boards may be connected. The 16 channel boards may be mixed on the RS485 bus with 8 way sounder boards 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of IO to satisfy any requirement.When using a simple two wire RS485 communications protocol these boards may be mounted locally to the control panel or distibuted on a bus up to 1200 metres long by using a suitable cable. The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output. Each channel may also be configured to produce a variety of input actions or respond to a varierty of output types.All channels can contribute to or respond to system wide cause and effects logic. Typical uses for IO boards include geographical LED mimic displays and plant alarm inputs. Standard Syncro control panels contain fixings for one sounder relay conventional detection or IO board which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.Features16 channelsEach channel configurable as input or outputInputs opto-isolatedOutputs open collector transistorSimple 2 wire connection to control panelUp to 32 boards supported per panel 512 InputOutput ChannelsInputs and outputs configurable as per field devicesFull cause and effects on all inputs and outputsMulti drop RS485 communicationsCan be used with other Syncro IO modules on the same panelCompatible with Syncro AS panels

GBP 232.79
1

Kentec Boxed Sigma XT Ancillary PCB cw 0.75 A PSU Surface K03750M2

Kentec K1822-00 Sigma A-XT Ancillary PCB

Kentec K376 Relay Board Four Way