14 results (0,13663 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

FC460PH Combined Optical and Heat Detector

Fireclass FC500MFI Multifunctional Interface V3.0

Fireclass FC64 AC Repeater Panel

Fireclass FC460P Optical Detector

FireClass FC460PC Multi-Sensor Smoke Heat and Carbon Monoxide Detector

Fireclass 20-118FC Combined Roshni Sounder Strobe Complete with Deep Base IP65 VID

Fireclass FC460H Thermal Heat Detector

Fireclass 557.202.080FC TLI800EN EN54 Approved Network Card

Fireclass 557.200.039FC TLI800ENG with PSU

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 183.06
1

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection CircuitsThe MTL7728 is an intrinsically safe zone-powered Zener-diode barrier for use in conventional fire detection systems for protection within hazardous areas.Each Zone contains two stages of pulse-tested Zener or forward- connected diodes and an infallible terminating resistor. In the event of an electrical fault in the safe area the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output-current limiting circuits are employed.Model MTL7728 is certified ia for all zones and IIC for all explosive atmospheres.The MTL7700 Series intrinsically safe shunt-diode safety barriers are innovative devices designed to provide exceptionally high packing densities straightforward installation and simplified connection commissioning and maintenance facilities. The MTL7700 Series include secondary replaceable fuses. These are useful where there is the possibility of faults occurring during commissioning which would otherwise blow the barriers internal safety fuses.One secondary replaceable fuse for each barrier channel is provided and is lower in value than the safety related fuse. Fuses are packaged in small mouldings which can be latched in a disconnect position to break the safe and hazardous areas during commissioning maintenance and fault finding thus avoiding the need for additional disconnect terminals.Key FeaturesRemovable colour-coded terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants - 6.3mm per channelProximity detector inputsCompatible terminal numbering and safety descriptionsDimensions 105 x 90 x 12.6mmNumber of Channels 1Supply Voltage 28 V dcSafety Voltage Maximum 26 V dcSafety Current Resistance 300ohmSafety Current Maximum 93mASignal Type AnalogueMinimum Operating Temperature -20CMaximum Operating Temperature 65CHazardous Area Certification ATEXOperating Temperature Range Maximum of 65 C

GBP 64.23
1

Fireclass 557.200.710FC FC64 DC Repeater 64 Zones

Fireclass 557.200.710FC FC64 DC Repeater 64 Zones

Fireclass 557.200.710FC FC64 DC Repeater 64 ZonesThe FC64RD Addressable fire alarm repeater panel is fully functioning and is compatible with the FC32 and FC64 range of fire alarm panels.Fire detection in big buildings can be extremely difficult. The FC64RD Compact addressable fire alarm zone repeater panel ensures that getting in to a fire alarm system and being able to interrogate the fire panel never needs to be difficult again.In an office building fire detection control panels may be located in reception but require numerous fire repeater panels around the building or on different floors.In schools the main fire alarm panel may be in the office but repeater panels are required around the school or at a security guard or caretakers house.The 24v FireClass Fire Alarm repeater panels also come in at just 4kg and provide a super compact repeater which is both aesthetically pleasing as well as retaining all the features and functions of the FireClass FC32 and FC64 addressable fire alarm control panels.The FireClass addressable repeater panel unit shows the same information as the main fire alarm control panel retains the full functionality of the main addressable fire alarm control panel including the ability to dial in to any other panel on the network to view and configure any point on the panel including RBus points.The FireClass repeater panel is almost half the depth and width of the larger repeater panels and also 22 shorter in height.Key FeaturesH x W x D 370 x 254 x 84 mmUp to 1000 addresses available on fire alarm control panel640 Character DisplayPermanently displays system statusDisplays temperature Carbon Monoxide CO level and smoke level at point in fire alarmViewing 3000 event logManual and Automatic walk test and reporting functionsAutomatic battery testFire Detector service functionsFront control panel controls enabling text and configuration changes Up to 24 panels networkableChoice of up to 5 fully functional repeaters with a maximum of 7 per panelWorks in conjunction with our Fireclass Addressable 64 Zone Control Panel

GBP 790.66
1